Case Study

Princeton Electric Plant Board

Utility: Princeton Electric Plant Board (PEPB)
Location: Princeton, Kentucky, USA
Infrastructure Type: Wood distribution poles

Princeton Electric Plant Board is a community-owned electric utility serving the Princeton, Kentucky area. Governed by a local board of directors, PEPB has made grid resilience a priority in recent years, including a state-backed initiative to strengthen its pole and line infrastructure against severe weather.

The Challenge

Like many aging distribution networks, a significant share of PEPB’s wood pole fleet is showing the effects of decades of exposure. Pole rot is the utility’s most pressing structural issue, driven by ground-line moisture, weathering, and the slow internal decay that comes with age.

PEPB is also contending with a second, less visible threat: copper wire theft. Utility poles carry copper grounding conductors that run from the pole into the ground, providing a critical safety path in the event of a lightning strike or electrical surge. Because copper holds resale value, these grounds are frequently targeted and cut for scrap. When a ground is compromised, especially at a transformer location, it can leave a hazardous voltage on the pole itself, creating a real safety risk for utility workers and the public.

This created a strategic challenge:

  • Widespread pole rot driven by ground-line moisture and age
  • Recurring copper grounding wire theft across the network
  • Safety risk to workers and the public when grounds are compromised
  • Full pole replacement addresses decay but not theft, and comes at a cost and timeline that strains smaller utilities

PEPB needed a solution that could restore pole strength while also making the grounding wire harder to reach and remove.

The Solution

GridWrap met with PEPB and conducted a hands-on field demonstration of its DEMIRWRAP® composite wrap system, applying it to a pole selected to represent one of PEPB’s most common failure conditions. The deployment included:

  • Field application of DEMIRWRAP® from ground line upward
  • Encasement of the exposed copper grounding conductor within the wrap
  • A single treatment addressing both structural decay and theft exposure

Because the wrap encases the pole from ground line upward, it also covers the exposed run of the copper grounding conductor, adding a physical barrier that makes the wire significantly harder to access and cut.

The Result

The demonstration confirmed DEMIRWRAP®’s effectiveness on a live pole in PEPB’s system, addressing both structural decay and copper theft exposure in a single application.

  • Structural restoration — the wrap reinforced the pole without requiring a full replacement, restoring structural integrity in place
  • Theft deterrence — the wrap covers the exposed grounding conductor, making it significantly harder to access and cut for scrap
  • Field-proven fit — successful application on PEPB’s infrastructure gives the utility a concrete reference point for wider deployment across its aging pole fleet